RTC 106
Optimisation through moisture measurement and compressibility measurement.
A moisture measurement on the belt feeder records the actual moisture in the sand and makes an exact determination of the pre-water possible. The formula value of the target moisture is controlled against the compressibility margin to the target value. If the compressibility is too low, the moisture target value is increased and, vice versa, if the compressibility too high, the moisture target value in the formula is decreased. Of the two measurement processes, this combination process improves the precision while not compromising the flow rate.
Task:
Bentonite-bonded moulding material is to be processed for the moulding facilities with reproducible, consistent values for the compressibility and mould stability.
________________________________________________________________________________________________________
Approach:
Samples are taken from the running mixing process and automatically used to determine compressibility and mould stability. These measured values will then be the parameters for water addition and bentonite dosing.
Solution:
The Rotocontrol RTC 106 gathers a sample quantity from the running mixing process. With the automatic measurement of the compressibility, the mould stability and the temperature, the currently needed amount of water is determined and subsequently added. For the bentonite requirements, a formula adjustment takes place. By means of the temperature measurement, the expected evaporation is determined and compensated by adding of water. Furthermore, all relevant data are saved and displayed on-line. Due to long-term storage, they will be available for future analysis.
Sämtliche Daten stehen durch die Langzeitspeicherungfür weitergehende Auswertungenzur Verfügung.
Advantages:
Simple installation
A proven improvement
irregular compressibility
regular compressibility
Illustration of recorded compressibility values from 2 production days, which show a definite equalisation since the operation of the RTC 106. During the irregular operation, only measured values were recorded.
Each batch is recorded along with a final measurement during the opening of the mixer. Our analysis programme DView_Analyse was used to illustrate the margin between target and actual value of over 200 consecutive batches. The deviations are minimal.